Influence of C-factor on the microtensile bond strength between fiber posts and resin luting agents
Ying-jie Wang1, Ling Zhang, Ji-hua Chen
1aLecturer, Department of General Dentistry, College of Stomatology, Fourth Military Medical University, Xian, PR China.
Purpose:
To propose an experimental model for assessing the interfacial strength between post and luting agent under clinically relevant conditions of post space diameter and cement layer thickness.
Materials And Methods:
DentinPost (Komet, DP) and GC (GC) glass fiber posts were tested. A sample of 22 posts per type was randomly subdivided into two equal groups based on the material for cementation: Panavia F 2.0 (Kuraray, PF) and MultiCore Flow (Ivoclar Vivadent, MF). Within each group, 2 subgroups were defined depending on the procedure for specimen preparation. In subgroup A (NO-M), the resin cement was incrementally stratified around a post centered within a plastic matrix until the latter was filled. In subgroup B (M), first a mold of resin cement with an artificial post space was created. Then, using the same cement, the post was luted into the dowel space. Microtensile beams were cut and loaded to measure post/cement interfacial strengths. For statistical analysis of the data, Kruskall-Wallis ANOVA was applied, followed by Dunn's Multiple Range test (p < 0.05).
Results:
Bond strengths in MPa were (median; 25th-75th percentile): DP/PF/M 4.5; 3.1-7.4; DP/PF/NO-M 9.2; 5.8-12.4; DP/MF/M 14.2; 10.2-20-6; DP/MF/NO-M 16.5; 13.1-21.7; GC/PF/M 7.6; 3.3-11.7; GC/PF/NO-M 7.8; 5.1-11-9; GC/MF/M 16.7; 14.3-3-22; GC/MF/NOM 20.4; 15.6-24. Irrespective of post type and of specimen preparation procedure, with or without mold, significantly higher bond strengths were measured for MF. On both post types, both cements achieved similar interfacial strengths regardless of the C-factor.
Conclusion:
The influence of a clinically relevant C-factor on the adhesion of resin cements to glass fiber posts was not statistically significant.
Related Concept Videos
Bonding and Strength of Aggregate
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Microcracking in Concrete
Factors Affecting Creep
Further, the water/cement ratio is critical, as a lower ratio increases concrete strength, thus reducing creep. The strength of the...