A reference database for the Stratec XCT-2000 peripheral quantitative computed tomography (pQCT) scanner in healthy
R L Ashby1, K A Ward, S A Roberts
1Clinical Radiology, Imaging Science & Cancer Studies, Stopford Building, University of Manchester, Manchester M13 9PT, UK.
Summary:
We have produced paediatric reference data for forearm sites using the Stratec XCT-2000 peripheral quantitative computed tomography scanner. These data are intended for clinical and research use and will assist in the interpretation of bone mineral density and bone geometric parameters at the distal and mid-shaft radius in children and young adults aged between 6-19 years.
Introduction:
Peripheral quantitative computed tomography (pQCT) provides measurements of bone mineral content (BMC), density (BMD) and bone geometry. There is a lack of reference data available for the interpretation of pQCT measurements in children and young adults. The aim of this study was to provide reference data at the distal and mid-shaft radius.
Methods:
pQCT was used to measure the 4% and 50% sites of the non-dominant radius in a cohort of healthy white Caucasian children and young adults aged between 5 and 25 years. The lambda, mu, sigma (LMS) technique was used to produce gender-specific reference centile curves and LMS tables for calculating individual standard deviations scores.
Results:
The study population consisted of 629 participants (380 males). Reference centile curves were produced; total and trabecular BMD for age (distal radius) and for age and height, bone area (distal and mid-shaft radius), cortical area, cortical thickness, BMC, axial moment of inertia, stress-strain index and muscle area (mid-shaft radius).
Conclusions:
We present gender-specific databases for the assessment of the distal and mid-shaft radius by pQCT. These data can be used as control data for research studies and allow the clinical interpretation of pQCT measurements in children and young adults by age and height.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET