Related Experiment Video
Updated: Jun 27, 2026

Gyroid Nickel Nanostructures from Diblock Copolymer Supramolecules
Published on: April 28, 2014
Synthesis, characterization and evaluation of ionic-imprinted polymers for solid-phase extraction of nickel from
Jacobo Otero-Romaní1, Antonio Moreda-Piñeiro, Pilar Bermejo-Barrera
1Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, University of Santiago de Compostela, Avenida das Ciencias, s/n. 15782 - Santiago de Compostela, Spain.
Abstract:
Several nickel ion imprinted polymers were prepared via precipitation polymerization using 4-vinylpyridine or 2-(diethylamino) ethyl methacrylate as monomers (vinylated reagents) and a cross-linking agent divinylbenzene in the presence of nickel(II) alone or nickel(II) and 8-hydroxyquinoline (non-vinylated reagent). For all cases, 2,2'-azobisisobutyronitrile (AIBN) was used as an initiator and an acetonitrile/toluene (3:1) mixture was chosen as a porogen. After packing the polymer particles into empty SPE cartridges, nickel(II) ions were removed by washing with 50mL of 2.0M nitric acid. Characterization of the polymer particles has been carried out by scanning electron microscopy, energy dispersive X-ray fluorescence and elemental analysis. The best nickel imprinting properties were given by polymers synthesized in the presence of 8-hydroxyquinoline and 2-(diethylamino) ethyl methacrylate as a monomer. The optimum pH for quantitative nickel retention was 8.5+/-0.5, while elution was completed with 2.5mL of 2.0M nitric acid. When using polymer masses of 300mg, sample volumes until 250mL can be passed through the cartridges without reaching the breakthrough volume. Therefore, a pre-concentration factor of 100 has been reached when eluting with 2.5mL of the elution solution. Electrothermal atomic absorption spectrometry has been used as a detector for nickel determination. The limit of detection of the method was 0.050mugL(-1) (pre-concentration factor of 100), while the relative standard deviation for eleven replicates was 6%. Accuracy of the method was assessed by analyzing different certified reference materials: SLEW-3 (estuarine water) and TM-23.3 and TM-24 (lake water).
Related Concept Videos
Ion Exchange
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Ion-Exchange Chromatography
Electrodeposition
Electrodeposition can...
Extraction: Advanced Methods
Washing, Drying, and Ignition of Precipitates

