Multivariate standardisation for non-linear calibration range in the chemiluminescence determination of chromium
L A Tortajada-Genaro1, P Campíns-Falcó
1Departamento Química, Escuela Técnica Superior Ingenieros Agrónomos, Universidad Politécnica Valencia, Camí de Vera s/n, 46022 Valencia, Spain.
Abstract:
Multivariate standardisation is proposed for the successful chemiluminescence determination of chromium based on luminol-hydrogen peroxide reaction. In an extended concentration range, non-linear calibration model is needed. The studied instrumental situations were different detection cells, instruments, assemblies, time and their possible combinations. Chemiluminescence kinetic registers have been transferred using piecewise direct standardisation (PDS) method. The optimisation of transfer parameters has been carried out based on the prediction residual error criteria. Non-linear principal component regression (NL-PCR) and non-linear partial least square regression (NL-PLS) were chosen for modelling the relationship signal-concentration of transferred registers. Good accuracy and precision were obtained for water samples. The concentrations of chromium were statistically in agreement with reference method values and with recovery studies. Therefore, it is possible to transfer chemiluminescence curves without loosing ability of prediction, even the presence of a non-linear behaviour.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Flame Photometry: Lab
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Calibration Curves: Correlation Coefficient