Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Evaluation of noninvasive methods to assess wave reflection and pulse transit time from the pressure waveform alone
Jan G Kips1, Ernst R Rietzschel, Marc L De Buyzere
1Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, De Pintelaan 185, B-9000 Gent, Belgium. Jan.Kips@UGent.be
Abstract:
Accurate quantification of pressure wave reflection requires separation of pressure in forward and backward components to calculate the reflection magnitude as the ratio of the amplitudes backward and forward pressure. To do so, measurement of aortic flow in addition to the pressure wave is mandatory, a limitation that can be overcome by replacing the unknown flow wave by an (uncalibrated) triangular estimate. Another extended application of this principle is the derivation of aortic pulse transit time from a single pulse recording. We verified these approximation techniques for reflection magnitude and transit time using carotid pressure and aortic flow waveforms measured noninvasively in the Asklepios Study (>2500 participants; 35 to 55 years of age). A triangular flow approximation using timing information from the measured aortic flow waveform yielded moderate agreement between reference and estimated reflection magnitude (R(2)=0.55). Approximating the flow by a more physiological waveform significantly improved these results (R(2)=0.74). Aortic transit time was assessed using pressure and measured or approximated flow waveforms, and results were compared with carotid-femoral transit times measured by Doppler ultrasound. Agreement between estimated and reference transit times was moderate (R(2)<0.29). Both for reflection magnitude and transit time, agreement between reference and approximated values further decreased when the approximated flow waveform was obtained using timing information from the pressure waveform. We conclude that, in our Asklepios population, results from pressure-based approximative methods to derive reflection magnitude or aortic pulse transit time differ substantially from the values obtained when using both measured pressure and flow information.
Related Concept Videos
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement