[Inaccuracy of glucose meters. Automatic correction for hematocrit variations and the presence of exogenous
J Goudable1, J Pollet, J A DuBois
1Université Lyon1, Inserm U870, HCL Lyon. joelle.goudable@chu-lyon.fr
Abstract:
Seven hospital-based glucose monitoring systems (meters) were evaluated with particular attention to those analytical interferences encountered in intensive care patients. Imprecision differed little between meters and remained altogether within acceptable limits. Inaccuracy, as measured by comparison with a hexokinase method presented with significant differences, yet without exceeding acceptable limits either. All meters but one showed an important bias when hematocrit departed from the reference interval. Two meters would not distinguish maltose from glucose. Three showed an important positive bias in the presence of acetaminophen and four a comparable bias in the presence of ascorbate. Only one meter was unaffected by both such exogenous interferences and hematocrit variations, owing to built-in hematocrit and electrochemical blank measuring devices. This meter also showed narrowest correlation with hexokinase methods. At a time when intensive care patients are being submitted to ever tighter glycemic control, it is desirable and our results show that it is now possible to tighten accordingly the acceptability criteria of glucose meters used to this end.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Hyperglycemia
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...