Related Experiment Video
Updated: Jun 27, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
The accuracy of multidetector computerized tomography for evaluating tumor thrombus in patients with renal cell
Thomas J Guzzo1, Phillip M Pierorazio, Edward M Schaeffer
1The James Buchanan Brady Urologic Institute, The Johns Hopkins Medical Institutions, Baltimore, Maryland 21287, USA. tguzzo1@jhmi.edu
Purpose:
New advances in computerized tomography, including multidetector computerized tomography with 3-dimensional reformatting has recently called into question the absolute need for magnetic resonance imaging for evaluating renal cell carcinoma with suspected venous involvement. We assessed the accuracy of multidetector computerized tomography for predicting tumor thrombus and the level of venous involvement in patients with renal cell carcinoma.
Materials And Methods:
We retrospectively reviewed clinical and pathological features in 41 patients with renal cell carcinoma who underwent staging multidetector computerized tomography before surgery. Multidetector computerized tomography findings regarding the presence and level of tumor thrombus were compared to findings at surgery and at final pathological evaluation. All multidetector computerized tomography studies were read by a single radiologist (EKF) before surgery.
Results:
When excluding patients with segmental venous involvement only, the concordance rate between multidetector computerized tomography and pathological findings was 84%. Multidetector computerized tomography accurately predicted the level of tumor thrombus in 26 of 27 patients (96%). Four cases of negative multidetector computerized tomography findings were up staged to renal vein involvement based on pathological findings. All 4 patients had early distal thrombi that did not change operative management.
Conclusions:
Multidetector computerized tomography with 3-dimensional mapping is an effective imaging modality for accurately characterizing the level of venous thrombus in patients with renal cell carcinoma. This modality effectively identified patients with clinically significant venous thrombus. Patients with renal cell carcinoma in whom multidetector computerized tomography fails to detect tumor thrombus are unlikely to have a tumor thrombus found at surgery that would change the surgical approach.
More Related Videos
10:26A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies