Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Oligo(ethylene glycol)-functionalized polycarbonate lipid nanoparticles for mRNA delivery with attenuated PEG immunogenicity.

Journal of controlled release : official journal of the Controlled Release Society·2026
Same author

Spontaneous Polarization Suppression of Exciton-Exciton Annihilation in Rhombohedral-Stacked Bilayer Molybdenum Disulfide.

ACS nano·2026
Same author

Corrigendum to "Transcranial focused ultrasound for identifying the neural substrate of conscious perception" [Neurosci. Biobehav. Rev. 180 (2025) 106485].

Neuroscience and biobehavioral reviews·2026
Same author

Protein-Capturing Microgel-Integrated Microneedle Array Patches for Enhanced Tip-Loading, Storage Stability, and Transdermal Delivery of Recombinant Proteins.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Direct Observation of Ultrafast Defect-Bound and Free Exciton Dynamics in Defect-Engineered WS<sub>2</sub> Monolayers.

ACS nano·2026
Same author

Utilizing AI CAD for early pandemic screening in chest radiographs.

Scientific reports·2026

Related Experiment Video

Updated: Jun 26, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

Positive contrast visualization for cellular magnetic resonance imaging using susceptibility-weighted echo-time

Young Beom Kim1, Ki Hyun Bae, Seung-Schik Yoo

  • 1Division of Electrical Engineering, School of Electrical Engineering and Computer Science, KAIST, Daejeon 305-701, Republic of Korea.

Magnetic Resonance Imaging
|December 25, 2008
PubMed
Summary

Researchers developed a new magnetic resonance imaging technique to highlight cells labeled with iron oxide particles. By comparing two different image types, they created a bright signal for these specific cells, making them easier to track in tumors. This method works on standard hospital scanners and helps visualize cell distribution.

Keywords:
iron oxide particlescellular trackingpositive contrasttumor imaging

Frequently Asked Questions

More Related Videos

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
11:27

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging

Published on: December 4, 2016

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

Related Experiment Videos

Last Updated: Jun 26, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
11:27

Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging

Published on: December 4, 2016

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

Area of Science:

  • Medical imaging and susceptibility-weighted echo-time encoding within radiology
  • Cellular tracking and molecular diagnostics in oncology

Background:

Traditional magnetic resonance imaging often struggles to distinguish labeled cells from surrounding tissues due to signal loss. This limitation hinders the precise tracking of therapeutic cells in clinical settings. No prior work had resolved the challenge of generating bright signals for iron oxide particles. That uncertainty drove the development of specialized acquisition sequences. Prior research has shown that magnetic field distortions around these particles typically cause dark spots. This gap motivated the search for alternative contrast mechanisms. Investigators sought to invert these dark signals into bright, readable markers. Such advancements are necessary for improving the sensitivity of cellular detection in vivo.

Purpose Of The Study:

The study aimed to develop a method for generating positive contrast specific to iron oxide labeled cells. This objective addresses the difficulty of identifying dark signal voids in standard magnetic resonance images. Researchers sought to improve the visibility of these cells during non-invasive tracking procedures. The motivation stemmed from the need for more accurate monitoring of therapeutic cell delivery. They focused on the susceptibility-weighted echo-time encoding technique to achieve this goal. This approach utilizes the physical properties of iron particles to create distinct bright markers. The team intended to validate this strategy through both controlled phantom tests and animal models. They hoped to demonstrate that this simple timing adjustment could be easily integrated into clinical workflows.

Main Methods:

The investigators designed a protocol to isolate signals from iron oxide particles using specific pulse sequences. They employed a subtraction algorithm comparing conventional spin-echo data with images acquired at shifted echo times. This review approach synthesized results from both phantom models and living subjects. Researchers placed labeled human epidermal carcinoma cells into gel matrices for initial calibration. They subsequently injected these marked cells into the flanks and limbs of nude mice. Unlabeled cells served as the internal control group for all animal trials. The team monitored tumor development over time using the optimized imaging parameters. Finally, they performed tissue staining to verify the spatial accuracy of the magnetic resonance signals.

Main Results:

The strongest finding demonstrates that the method reliably produces bright signals for iron oxide labeled cells. In vitro testing established a minimum detection threshold of 5000 labeled cells per sample. The researchers observed that the count of pixels showing positive contrast increased linearly with the number of labeled cells. Animal experiments confirmed the successful visualization of tumor growth originating from the injected cell populations. Comparison with control sites showed that unlabeled cells did not produce these bright markers. The data indicate that the echo-time shift principle effectively highlights magnetic susceptibility effects. These results suggest that the technique maintains high specificity for the target particles. The study provides quantitative evidence that this approach is suitable for tracking cell distribution in vivo.

Conclusions:

The authors suggest that their technique provides a reliable way to track iron oxide labeled cells. This approach effectively converts signal voids into bright spots for better visualization. Their findings indicate that the method functions well within standard clinical hardware environments. The researchers propose that this simple shift in timing allows for robust detection of labeled populations. Data from their experiments confirm that the signal intensity correlates with cell density. They conclude that this imaging strategy offers a practical solution for monitoring tumor progression. The study highlights the potential for non-invasive tracking of therapeutic agents in living subjects. Future applications may benefit from the ease of implementing this sequence on existing scanners.

The researchers propose a subtraction method between standard spin-echo and echo-time shifted images. This process isolates the magnetic susceptibility effects of the iron oxide particles, resulting in a bright, positive signal rather than the typical dark void seen in conventional scans.

The study utilizes superparamagnetic iron oxide particles as the primary contrast agent. These particles create local magnetic field disturbances that the imaging sequence detects, allowing for the specific identification of labeled human epidermal carcinoma cells within the gel phantoms and animal models.

A clinical scanner is necessary to implement the echo-time shift principle. The authors emphasize that this hardware requirement is minimal, as the sequence relies on standard pulse programming rather than specialized, non-clinical equipment, facilitating broader adoption in medical research settings.

The researchers used histological analysis to validate the presence of the labeled cells. This biological data served as the ground truth to confirm that the positive contrast signals observed in the magnetic resonance images accurately represented the actual distribution of the injected tumor cells.

The team measured a minimum detection threshold of 5000 labeled cells in vitro. They observed that the total number of pixels displaying positive contrast increased in direct proportion to the quantity of iron oxide loaded cells present in the sample.

The authors propose that their method allows for the non-invasive monitoring of tumor growth. By tracking the bright signals over time, clinicians could potentially observe the spatial expansion of labeled cell populations within a living host without needing invasive procedures.