Related Experiment Video
Updated: Jun 26, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Dynamic half-Fourier single-shot turbo spin echo for assessment of deep venous thrombosis: initial observations
Ivan Pedrosa1, Long Ngo, Jesse Wei
1Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA 02215, USA. ipedrosa@bidmc.harvard.edu
Objective:
The objective of this study was to retrospectively analyze the value of dynamic half-Fourier single-shot turbo spin echo (HASTE) imaging in patients with suspected deep venous thrombosis (DVT).
Materials And Methods:
Fifty-five veins in 24 patients were interrogated using a HASTE sequence with the patients relaxed and in various degrees of Valsalva. Veins were analyzed for changes in caliber (+CAL) and signal intensity (+SI) or in their absence (-CAL and -SI, respectively) and compared with the presence of thrombus on gadolinium-enhanced magnetic resonance imaging.
Results:
There was no thrombus in veins with the +CAL, +SI pattern (n=40) (P<.01). Five of seven veins (71.4%) with the -CAL, -SI pattern had thrombus (P<.01). A qualitative change in CAL had a sensitivity of 100% and a specificity of 91% for the presence of thrombus. An increase of 1.5 mm in CAL had a sensitivity of 100% and a specificity of 93% for this diagnosis.
Conclusion:
Dynamic HASTE imaging offers a physiological method to evaluate veins for deep venous thrombosis.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation