Determination of hair nicotine by gas chromatography-mass spectrometry
Che Nin Man1, Syazwani Ismail, Gam Lay Harn
1National Poison Centre, Universiti Sains Malaysia, 11800 Penang, Malaysia. kaknin337@yahoo.com
Abstract:
Hair nicotine is a known biomarker for monitoring long-term environmental tobacco smoke (ETS) exposure and smoking status. In general, hair nicotine assay involves alkaline digestion, extraction and instrumental analysis. The gas chromatography-mass spectrometry (GC-MS) assay currently developed has shown to be of high throughput with average approximately 100 hair samples being extracted and analyzed per day. This was achieved through simplified extraction procedure and shortened GC analysis time. The extraction was improved by using small volume (0.4 mL) of organic solvent that does not require further evaporation and salting steps prior to GC-MS analysis. Furthermore, the amount of hair utilized in the extraction was very little (5 mg) while the sensitivity and selectivity of the assay is equal, if not better than other established methods. The linearity of the assay (r(2)>0.995), limit of quantitation (0.04 ng/mg hair), within- and between-assays accuracies and precisions (<11.4%) and mean recovery (92.6%) were within the acceptable range.
More Related Videos
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
07:38A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...