Interfaces and humidification for noninvasive mechanical ventilation
Stefano Nava1, Paolo Navalesi, Cesare Gregoretti
1Respiratory Intensive Care Unit, Istituto Scientifico di Pavia, Fondazione S Maugeri, Istituto di Ricovero e Cura a Carattere Scientifico, Pavia, Italy. stefano.nava@fsm.it
Abstract:
During noninvasive ventilation (NIV) for acute respiratory failure, the patient's comfort may be less important than the efficacy of the treatment. However, mask fit and care are needed to prevent skin damage and air leaks that can dramatically reduce patient tolerance and the efficacy of NIV. Choice of interface is a major determinant of NIV success or failure. The number and types of NIV interface has increased and new types are in development. Oronasal mask is the most commonly used interface in acute respiratory failure, followed by nasal mask, helmet, and mouthpiece. There is no perfect NIV interface, and interface choice requires careful evaluation of the patient's characteristics, ventilation modes, and type of acute respiratory failure. Every effort should be made to minimize air leaks, maximize patient comfort, and optimize patient-ventilator interaction. Technological issues to consider when choosing the NIV interface include dead space (dynamic, apparatus, and physiologic), the site and type of exhalation port, and the functioning of the ventilator algorithm with different masks. Heating and humidification may be needed to prevent adverse effects from cool dry gas. Heated humidifier provides better CO(2) clearance and lower work of breathing than does heat-and-moisture exchanger, because heated humidifier adds less dead space.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...