Quasi-analytical determination of noise-induced error limits in lidar retrieval of aerosol backscatter coefficient by

Michaël Sicard1, Adolfo Comerón, Francisco Rocadenbosch

  • 1Remote Sensing Laboratory, Department of Signal Theory and Communications, Universitat Politènica de Catalunya. msicard@tsc.upc.edu

Applied Optics
|January 13, 2009
PubMed

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Application of Linearization and Approximation01:29

Application of Linearization and Approximation

A drone flying through complex terrain often relies on more than one sensing method to estimate small changes in altitude. Along with direct measurements, air pressure provides a useful indirect indicator of vertical movement. Atmospheric pressure decreases as altitude increases, and this relationship is commonly described using an exponential model. Although accurate, converting pressure measurements into altitude values requires calculations that are too complex to perform repeatedly during...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Contaminants and Errors01:16

Contaminants and Errors

Effective sample preparation is crucial for accurate and reliable laboratory analysis. During this process, two significant sources of error can arise: concentration bias from improper sample splitting and contamination caused by methods used to reduce particle size, such as grinding or homogenization. Identifying and minimizing these potential errors is crucial to ensuring the validity of the analysis.
Another key consideration is determining the appropriate number of samples required to...