A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Atrioventricular delays, cardiac output and diastolic function in patients with implanted dual chamber pacing and
F Akbarzadeh1, Mehrnoush Toufan
1Cardiovascular Research Center of Shahid Madani Hospital, Tabriz University of Medical Sciences, Tabriz, Iran.
Abstract:
The Cardiac Output (CO), Filling Time (FT) and Myocardial Performance Index (MPI) derived optimal atrioventricular delay (AVD), were compared and systolic and diastolic performance at every optimal AVD were analyzed. Thirty-two patients with implanted DDD pacemaker were investigated from implantation time to 6 months following PM implantation, in Cardiovascular Research Center of Tabriz University of Medical Sciences. The evaluation was performed during AV sequential pacing with different programmed AVDS ranged from 100 to 200 msec by steps of 20-30 msec. At every AVD, the following parameters were measured: FT, mitral VTI, ET, aortic VTI, ICT and IRT. CO and FT derived optimal AVDs were significantly different (146 +/- 37 and 126 +/- 35 msec, respectively), but their difference with MPI derived optimal AVDs was not significant (130 +/- 28 msec). ICT/ET was similar at CO, FT and MPI derived optimal AVD (0.24 +/- 0.10, 0.22 +/- 0.05 and 0.20 +/- 0.07, respectively). IRT/ET ratio was similar at CO, FT and MPI derived optimal AVDs (0.46 +/- 0.14, 0.45 +/- 0.10 and 0.42 +/- 0.10, respectively). Different methods indicate different optimal AVDs. However analysis of systolic and diastolic performance shows that different AVDs result in similar systolic or diastolic performance. At MPI optimized AVD, a high CO combined with the most advantageous conditions of both isovolumic contraction and relaxation phases is achieved.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Mitral Stenosis I: Introduction
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...