Related Experiment Video
Updated: Jun 26, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Early stent thrombosis because of stent dislodgement in a coronary artery aneurysm
Kazumasa Sugimoto1, Yoshio Kobayashi, Hirofumi Miyahara
1Department of Cardiovascular Science and Medicine, Chiba University Graduate School of Medicine, Chuo-ku, Chiba, Japan.
Insights
Early stent thrombosis can be catastrophic. This case report highlights a rare cause: bare metal stent dislodgement due to a dissolved mural thrombus in an unappreciated coronary artery aneurysm.
Area of Science:
- Cardiology
- Interventional Cardiology
- Medical Case Reports
Background:
- Stent thrombosis is a severe complication following coronary stenting, often leading to acute myocardial infarction or death.
- Mechanical factors like stent underexpansion and vessel dissection are known risks.
- Early identification and management of risk factors are crucial in interventional cardiology.
Observation:
- This case report details an instance of early stent thrombosis.
- The thrombosis was linked to the dislodgement of a bare metal stent.
- The dislodgement occurred due to the dissolution of a mural thrombus within a previously unrecognized coronary artery aneurysm.
Findings:
- A rare cause of early stent thrombosis was identified: bare metal stent dislodgement.
- The underlying mechanism involved the dissolution of a mural thrombus.
- An unappreciated coronary artery aneurysm was the anatomical substrate for the thrombus and subsequent dislodgement.
Implications:
- This case underscores the importance of considering anatomical variations like coronary artery aneurysms in patients presenting with stent thrombosis.
- It highlights a unique mechanism of stent failure beyond typical mechanical issues.
- Further investigation into the management of coronary artery aneurysms in stented segments may be warranted.
Abstract:
Stent thrombosis is one of the most feared complications after coronary stenting, because it often presents in a catastrophic way, triggering death or acute myocardial infarction. Previous studies report mechanical risk factors of stent thrombosis such as stent underexpansion and vessel dissection. This is a case report of early stent thrombosis associated with bare metal stent dislodgement because of dissolution of a mural thrombus in an unappreciated coronary artery aneurysm.
Related Concept Videos
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Aneurysm I: Introduction
Aneurysm III: Interprofessional Care
Coronary Artery Disease II: Pathophysiology
Acute Coronary Syndrome III: Diagnostic Studies