Use of activated graphitized carbon chips for liquid chromatography/mass spectrometric and tandem mass spectrometric
William R Alley1, Yehia Mechref, Milos V Novotny
1National Center for Glycomics and Glycoproteomics, Department of Chemistry, Indiana University, Bloomington, IN 47405, USA.
Abstract:
Protein glycosylation has a significant medical importance as changes in glycosylation patterns have been associated with a number of diseases. Therefore, monitoring potential changes in glycan profiles, and the microheterogeneities associated with glycosylation sites, are becoming increasingly important in the search for disease biomarkers. Highly efficient separations and sensitive methods must be developed to effectively monitor changes in the glycoproteome. These methods must not discriminate against hydrophobic or hydrophilic analytes. The use of activated graphitized carbon as a desalting media and a stationary phase for the purification and the separation of glycans, and as a stationary phase for the separation of small glycopeptides, has previously been reported. Here, we describe the use of activated graphitized carbon as a stationary phase for the separation of hydrophilic tryptic glycopeptides, employing a chip-based liquid chromatographic (LC) system. The capabilities of both activated graphitized carbon and C(18) LC chips for the characterization of the glycopeptides appeared to be comparable. Adequate retention time reproducibility was achieved for both packing types in the chip format. However, hydrophilic glycopeptides were preferentially retained on the activated graphitized carbon chip, thus allowing the identification of hydrophilic glycopeptides which were not effectively retained on C(18) chips. On the other hand, hydrophobic glycopeptides were better retained on C(18) chips. Characterization of the glycosylation sites of glycoproteins possessing both hydrophilic and hydrophobic glycopeptides is comprehensively achieved using both media. This is feasible considering the limited amount of sample required per analysis (<1 pmol). The performance of both media also appeared comparable when analyzing a four-protein mixture. Similar sequence coverage and MASCOT ion scores were observed for all proteins when using either stationary phase.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
High-Performance Liquid Chromatography: Instrumentation