A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Robust ballistocardiogram acquisition for home monitoring
O T Inan1, M Etemadi, R M Wiard
1Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA. omerie@stanford.edu
Abstract:
The ballistocardiogram (BCG) measures the reaction of the body to cardiac ejection forces, and is an effective, non-invasive means of evaluating cardiovascular function. A simple, robust method is presented for acquiring high-quality, repeatable BCG signals from a modified, commercially available scale. The measured BCG waveforms for all subjects qualitatively matched values in the existing literature and physiologic expectations in terms of timing and IJ amplitude. Additionally, the BCG IJ amplitude was shown to be correlated with diastolic filling time for a subject with premature atrial contractions, demonstrating the sensitivity of the apparatus to beat-by-beat hemodynamic changes. The signal-to-noise ratio (SNR) of the BCG was estimated using two methods, and the average SNR over all subjects was greater than 12 for both estimates. The BCG measurement was shown to be repeatable over 50 recordings taken from the same subject over a three week period. This approach could allow patients at home to monitor trends in cardiovascular health.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias