Related Experiment Video
Updated: Jun 26, 2026

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Rapid column-mode removal of arsenate from water by crosslinked poly(allylamine) resin
1Department of Applied Chemistry and Biochemistry, Kumamoto University, Kurokami 2-39-1, Kumamoto 860-8555, Japan.
Abstract:
Performances of crosslinked poly(allylamine) resin (PAA) as arsenate (As(V)) adsorbent were studied using a column packed with PAA in hydrochloride form. PAA has a high amino group content of 14.6 mmol/g in free amine form and a high chloride content of 10.2 mmol/g in hydrochloride form. Its wet volumes in water were 4.5 and 3.1 mL/g in hydrochloride and free amine forms, respectively, indicating its high hydrophilicity. Breakthrough capacities for As(V) were evaluated changing conditions of adsorption operations: pH of feeds from 2.2 to 7.0, concentration of As(V) in feeds from 0.020 to 2.0 mM, and feed flow rate from 250 to 4000 h(-1) in space velocity. Breakthrough capacities increased from 2.6 to 3.4 mmol/g with a decrease in pH from 7.0 and 2.2, and also from 0.81 to 2.8 mmol/g with an increase in As(V) concentration from 0.020 to 2.0mM. When feed flow rate increased from 250 to 4000 h(-1), breakthrough capacities changed form 3.5 to 0.81 mmol/g. Because of non-Hofmeister anion selectivity behavior of PAA, the interference of chloride and nitrate was minor. Although PAA slightly preferred As(V) to sulfate, the latter more markedly interfered with uptake of As(V) than chloride and nitrate. Competitive uptake of As(V) and phosphate revealed that PAA slightly preferred phosphate to As(V). The adsorbed As(V) was quantitatively eluted with 2M HCl and PAA was simultaneously regenerated into hydrochloride form. All results were obtained using the same column without change of the packed PAA and any deterioration in column performances for 4 months.
More Related Videos
06:52Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron (Oxy)Hydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Ion Exchange
Precipitation and Co-precipitation
Coagulation
Factors Affecting Solubility
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography