Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Non-invasive measurement of Valsalva-induced hemodynamic changes on a bathroom scale ballistocardiograph
Omer T Inan1, Mozziyar Etemadi, Richard M Wiard
1Stanford University Electrical Engineering Department, Stanford, CA 94305, USA. omeri@stanford.edu
Abstract:
Unobtrusive and compact methods for monitoring time varying hemodynamic trends can allow physicians to monitor heart failure of outpatients at home. In this paper, the ballistocardiogram (BCG), measured on a modified commercial bathroom scale, is proposed as a viable option for this important need. The BCG measures the reaction force of the body to cardiac ejection of blood and is a non-invasive tool for evaluating cardiovascular function. The Valsalva maneuver was used to modulate the hemodynamics in a well documented manner, and BCG signals were acquired from 15 subjects. The electrocardiogram (ECG) was simultaneously obtained to measure the electrical to mechanical delay in ventricular contraction: the interval from the ECG R-wave peak to the BCG J-wave peak. This interval, called the RJ interval, decreased for all subjects following the release of intrathoracic strain compared to the resting value, suggesting that it is inversely correlated to cardiac contractility. The power spectrum magnitude of the BCGs showed that the high frequency content increased after release, also consistent with increased contractility (faster ejection). Additionally, J-wave amplitudes increased following release, suggesting that it is correlated to stroke volume. Since RJ interval computation required the ECG, BCG J-wave rise time was proposed as an alternative for evaluating cardiac contractility. The correlation between this rise time and RJ interval was high (R2=0.78).
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement