A hydrostatic calibration method for the design of wearable PAT-based blood pressure monitoring devices
Related Experiment Video
Updated: Jun 26, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Yinbo Liu1, Carmen C Y Poon, Yuan-Ting Zhang
1Joint Research Centre for Biomedical Engineering Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong.
Abstract:
Pulse arrival time (PAT) has been proposed for measuring blood pressure (BP) noninvasively and continuously. A challenge of the PAT-based BP measurement technique is to calibrate it individually. The objective of this study is to examine a previously proposed model-based calibration method utilizing hydrostatic pressure for BP estimation. A preliminary experiment has been conducted on eight subjects aged from 23 to 36. Each subject was asked to raise their right arms to five different heights (H). At each height, PAT and brachial BP were measured from the elevated arm and the resting arm respectively. The data recorded at each height were used to calibrate a subject-dependent coefficient b which was then used to estimate his/her brachial SBP before and after exercise. It was found that the estimation results were influenced by H and k, which is a constant time interval subtracted from PAT. In this study, the estimation errors were found to be more sensitive to H than to k for -30< or =H< or =30 cm and 40< or =k< or =70 ms.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure