Estimation of the aortic pressure waveform from a peripheral artery pressure waveform via an adaptive transfer
Gokul Swamy1, Ramakrishna Mukkamala, N Olivier
1Department of Electrical and Computer Engineering, East Lansing, MI 48824, USA. swamygok@msu.edu
Abstract:
We developed a new technique to estimate the aortic pressure (AP) waveform from a single peripheral artery pressure (PAP) waveform. The technique 1) employs a parallel tube model of the arterial tree to establish a transfer function relating PAP to AP with unknown parameters; 2) estimates the parameters from the measured PAP waveform, along with a single non-invasive measurement of the wave transmission delay from the aorta to the peripheral artery measurement site, by exploiting the fact that aortic flow is zero during diastole; and 3) applies the transfer function to the PAP waveform to predict the unmeasured AP waveform. In this way, in contrast to the conventional generalized transfer function paradigm, the transfer function is able to adapt to the inter-subject and temporal variability of the arterial tree. We applied this adaptive transfer function technique to PAP waveforms measured from five dogs instrumented with reference AP catheters during various hemodynamic interventions. Our results showed that the technique was able to reliably estimate the AP waveform with an overall error of 4.2 mmHg. For comparison, the corresponding errors of two previously proposed generalized transfer functions trained on a subset of the same canine data were, on average, 19% larger.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.