Multiscale sample entropy in heart rate variability of aortic stenosis patients
José F Valencia1, Alberto Porta, Montserrat Vallverdú
1Dept. ESAII, Centre for Biomedical Engineering Research, Technical University of Catalonia, CIBER of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Barcelona, Spain. jose.fernando.valencia@upc.edu
Abstract:
In the present document the multiscale entropy (MSE) methodology has been applied to analyze the complex behavior of the heart rate variability (HRV), in patients with aortic stenosis (AS). A set of healthy voluntaries have been used as a control group. MSE analysis calculates an entropy rate over different time scales to assess the complexity of time series, evaluating short-term and long-term correlations. Daytime and nighttime have been considered to study variations of the complexity inside the same group of population. A statistical analysis showed that entropy was significantly higher in healthy subjects than in AS subjects in all the scales during daytime, with exception at scale 1. During nighttime, entropy in healthy subjects was significantly higher than in AS subjects only in scales from 1 to 7. Multiscale entropy is helpful to characterize AS patients and distinguish them from healthy subjects.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Pulse
The pulse serves as a clinical indicator...
Assessment of blood pressure in brachial artery(two-step method)
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...