Related Experiment Video
Updated: Jun 26, 2026

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Physiological responses to exercise on different models of the concept II rowing ergometer
Andrew J Vogler1, Anthony J Rice, Robert T Withers
1Dept of Physiology, Australian Institute of Sport, Canberra, ACT, Australia.
The Concept II model D (IID) rowing ergometer yields nearly identical physiological responses to the older model C (IIC). Results from either ergometer can be directly compared for rowing performance testing.
Area of Science:
- Exercise Physiology
- Biomechanics
- Sports Science
Background:
- The Concept II model C (IIC) rowing ergometer, a standard in performance assessment, was succeeded by the Concept II model D (IID).
- Design modifications in the IID ergometer raised questions about potential alterations in resistance characteristics and rowing technique.
- These potential changes could impact the comparability of ergometer test results between the two models.
Purpose of the Study:
- To evaluate and compare the physiological responses of national-level rowers using the Concept II model C (IIC) and Concept II model D (IID) rowing ergometers.
- To determine if the updated IID ergometer produces comparable results to the IIC ergometer during submaximal and maximal rowing tests.
- To assess the influence of ergometer model on key physiological markers and performance metrics.
Main Methods:
- Eight national-level rowers participated in the study.
- Participants completed both submaximal progressive incremental tests and maximal-performance time trials on both IIC and IID ergometers.
- Tests were conducted with a 48-72 hour separation, using standardized drag-factor settings to ensure comparability.
Main Results:
- No significant differences were observed in power output, oxygen consumption, rowing economy, heart rate, stroke rate, or rating of perceived exertion between the IIC and IID ergometers.
- Blood lactate thresholds (LT1 and LT2) were also found to be similar between the two ergometer models.
- A minor, statistically significant difference in blood lactate concentration at LT (0.2 mmol/L) was noted, but deemed clinically insignificant.
Conclusions:
- The physiological responses elicited by rowing on the Concept II model C and Concept II model D ergometers are virtually identical.
- Performance testing results obtained from either the IIC or IID ergometer can be directly compared without significant concern for ergometer-induced variability.
- The updated IID ergometer maintains the validity of established rowing performance metrics from the IIC model.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
Related Concept Videos
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's proficiency in drug...