Related Experiment Video
Updated: Jun 26, 2026

An In Vitro Bladder Model of Catheter-Associated Urinary Tract Infection
Published on: June 24, 2025
Dose requirements for UVC disinfection of catheter biofilms
Jimmy Bak1, Søren D Ladefoged, Michael Tvede
1DTU Fotonik, Technical University of Denmark, Roskilde, Denmark. jimmy.bak@risoe.dk
Abstract:
Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required doses to kill catheter biofilm. Given these doses and the power of available UVC light sources, calculation of the necessary treatment times is then possible. To determine the required doses, contaminated urinary catheters were used as test samples and UVC treated in vitro. Patient catheters (n = 67) were collected and cut into segments of equal size and treated with various UVC doses. After treatment, the biofilm was removed by scraping and quantified by counting colony forming units. Percentage killing rates were determined by calculating ratios between UVC-treated samples and controls (no UVC treatment). Mean killing rates were 89.6% (0.5 min), 98% (2 min), and 99% (60 min). Approximately 99% killing was obtained with a UVC dose of 15 kJ m(-2). This dose, which is about 100 to 1000 times greater than the lethal dose for planktonic cells, is expected to be the maximum dose required to maintain newly inserted catheters free of contamination. The combination of high doses required to kill mature biofilm and the limited effect of current UVC light sources result in a relative long treatment time ( approximately 60 min). If a UVC-based method is to be of practical use for disinfection of catheters in the clinic, repeated preventive treatments should be carried out on newly inserted catheters.
Related Concept Videos
Hand hygiene
Hand washing...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...