Published on: October 25, 2015
Early conception factor lateral flow assays for pregnancy in the mare
E Marino1, W R Threlfall, R A Schwarze
1Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, 30425 McPeck Road, Richwood, OH 43344, United States. mobprincess41@hotmail.com
Theriogenology
|February 3, 2009
Summary
The ECF lateral flow assay is inaccurate for detecting non-pregnancy in mares. Both human and electronic readers showed high false positive rates, making the test unreliable for equine reproductive diagnostics.
Area of Science:
- Veterinary Medicine
- Animal Reproduction
- Diagnostic Assays
Background:
- The ECF lateral flow assay is commercially available for determining non-pregnancy in mares.
- Accurate pregnancy diagnosis in mares is crucial for effective herd management and reproductive efficiency.
Purpose of the Study:
- To evaluate the diagnostic accuracy of the ECF lateral flow assay in mares.
- To assess the performance of the electronic reader associated with the ECF test.
- To determine the agreement between human readers and the electronic reader for ECF test interpretation.
Main Methods:
- Serum samples were collected from mares in anestrus, cycling (non-inseminated), and inseminated states.
- Samples were tested using the ECF lateral flow assay at two independent laboratories.
- Test results were interpreted by two human readers and an electronic reader.
Main Results:
- Specificity ranged from 0.07 to 0.16, and negative predictive value ranged from 0.15 to 0.33.
- Overall accuracy of the ECF test was between 0.43 and 0.52.
- High false positive rates were observed for both human and electronic readers across different reproductive states, with the electronic reader showing 80.0% false positives in anestrus mares and 83.9% in cycling mares.
Conclusions:
- The ECF lateral flow assay demonstrates poor accuracy for determining non-pregnancy in mares.
- The electronic reader does not improve the test's accuracy or predictive values.
- The assay is unreliable for equine non-pregnancy diagnosis, irrespective of the interpretation method used.