Herbert Oberacher1, Florian Pitterl
1Institute of Legal Medicine, Innsbruck Medical University, Innsbruck, Austria. herbert.oberacher@i-med.ac.at
Abstract:
The usability of a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for the tandem mass spectrometric sequencing of oligodeoxynuleotides was investigated. The sample set consisted of 21 synthetic oligodeoxynucleotides ranging in length from 5 to 42 nucleotides. The sequences were randomly selected. For the majority of tested oligonucleotides, two or three different charge states were selected as precursor ions. Each precursor ion was fragmented applying several different collision voltages. Overall 282 fragment ion mass spectra were acquired. Computer-aided interpretation of fragment ion mass spectra was accomplished with a recently introduced comparative sequencing algorithm (COMPAS). The applied version of COMPAS was specifically optimized for the interpretation of information-rich spectra obtained on the QqTOF. Sequences of oligodeoxynucleotides as large as 26-mers were correctly verified in >94% of cases (182 of 192 spectra acquired). Fragment ion mass spectra of larger oligonucleotides were not specific enough for sequencing. Because of the occurrence of extensive internal fragmentation causing low sequence coverage paired with a high probability of assigning fragment ions to wrong sequences, tandem mass spectra obtained from oligonucleotides consisting of 30 and more nucleotides could not be used for sequence verification neither manually nor with COMPAS. (c) 2009 Wiley Periodicals, Inc. Biopolymers 91: 401-409, 2009.
Related Concept Videos
RNA-seq
Before the discovery of RNA-seq, microarray-based methods and Sanger sequencing were used for transcriptome analysis. However, while microarray-based...
Sanger Sequencing
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features.
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...