Related Experiment Video
Updated: Jun 25, 2026

Systematic Bronchoscopy: the Four Landmarks Approach
Published on: June 23, 2023
Cervical spine motion during flexible bronchoscopy compared with the Lo-Pro GlideScope
D M Wong1, A Prabhu, S Chakraborty
1Department of Anaesthesia, Toronto Western Hospital, Canada. danielm.ywong@gmail.com
Background:
The most appropriate device for tracheal intubation in patients with potential cervical spine injury remains controversial. We hypothesized that the Lo-Pro GlideScope (LP-G) videolaryngoscope would not cause significantly greater cervical spine movement than fibreoptic bronchoscopy even in the non-immobilized spine.
Methods:
Twenty-eight healthy adults requiring intubation for radiographic procedures were randomized to either the LP-G or the flexible bronchoscope (FB) devices. Continuous fluoroscopy was used to assess cervical spine movement during tracheal intubation. The point of maximum movement was compared with baseline for change in angulation between Occiput (Occ)-C1, Occ-C2, Occ-C4, Occ-C5, C1-2, C2-4, and C4-5. Measurements were made by two independent observers. The change in angulation was also measured for tongue pull and jaw thrust, manoeuvres for enlarging the pharyngeal space, before FB intubation.
Results:
LP-G resulted in greater cervical extension compared with FB for every angle calculated, statistically significant between Occ-C1 (P<0.05), Occ-C2 (P<0.05), and Occ-C4 (P<0.01). Tongue pull resulted in significantly less cervical spine motion than FB intubation at Occ-C1, Occ-C2, Occ-C4, and Occ-C5 (P<0.05). When jaw thrust was added to tongue pull, there was a tendency for greater movement than FB intubation at Occ-C1, Occ-C2, and Occ-C3. This was statistically significant at Occ-C1 and Occ-C3 (P<0.05) for one of the two observers.
Conclusions:
During intubation under general anaesthesia, LP-G resulted in greater cervical movement than FB when no cervical immobilization was used in adults without cervical disease. Airway manoeuvres performed before FB, especially jaw thrust, also resulted in cervical spine movement.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures V: ERCP
Patient...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...