Related Experiment Video
Updated: Jun 25, 2026

Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
Radiofrequency ablation of subpleural lung malignancy: reduced pain using an artificially created pneumothorax
Edward W Lee1, Robert D Suh, Michelle R Zeidler
1Department of Radiological Sciences, Thoracic Imaging and Intervention, UCLA Medical Center, David Geffen School of Medicine at UCLA, 10833 Le Conte Avenue, B2-168, Los Angeles, CA 90095-1721, USA. EdwardLee@mednet.ucla.edu
Abstract:
One of the main issues with radiofrequency (RF) ablation of the subpleural lung malignancy is pain management during and after RF ablation. In this article, we present a case that utilized a technique to decrease the pain associated with RF ablation of a malignancy located within the subpleural lung. Under CT guidance, we created an artificial pneumothorax prior to the RF ablation, which resulted in minimizing the pain usually experienced during and after the procedure. It also decreased the amount of pain medications usually used in patients undergoing RF ablation of a subpleural lung lesion.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Pneumothorax II: Pathophysiology
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.