Related Experiment Video
Updated: Jun 25, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Deep vein thrombosis using noncontrast-enhanced MR venography with electrocardiographically gated three-dimensional
Atsushi Ono1, Kenya Murase, Toshitaka Taniguchi
1Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Yamadaoka, Suita, Osaka, Japan.
Abstract:
Three noncontrast-enhanced MR venography techniques are presented for assessing deep vein thrombosis (DVT) at 0.5 T in patients with metallic implants. Two cardiac-gated 3D half-Fourier FSE fresh blood imaging sequences with flow-refocusing pulses (FR-FBI) in the read-out (RO) direction and without FR pulses (non-FR-FBI) were developed for slower-flowing blood. For faster flowing blood, a swap phase-encode arterial double-subtraction elimination (SPADE) technique was developed. The three techniques were assessed both quantitatively using signal-to-noise (SNR) and contrast-noise-ratio (CNR) measurements and qualitatively by subjective image analysis in 15 volunteers. SPADE was compared to FR-FBI in the pelvic veins and FR-FBI was compared to non-FR-FBI in the thigh and calf veins. Both SPADE and FR-FBI techniques produced significantly higher SNRs, CNRs, and image quality in each comparative study (P<0.001). Five patients with metallic implants and confirmed DVT underwent SPADE (pelvic veins) and FR-FBI (thigh and calf veins) examinations and the results were compared to conventional venography. The SPADE and FR-FBI images showed all DVTs from all five patients without interference from implant susceptibility artifacts. The excellent image quality produced by both SPADE and FR-FBI throughout peripheral vasculature demonstrates their promise for detecting DVT in postsurgery patients.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI