Related Experiment Video
Updated: Jun 25, 2026

Analyzing Large Protein Complexes by Structural Mass Spectrometry
Published on: June 19, 2010
Size exclusion chromatography coupled to electrospray ionization mass spectrometry for analysis and quantitative
Anne-Christine Schmidt1, Benjamin Fahlbusch, Matthias Otto
1TU Bergakademie Freiberg, Faculty of Chemistry and Physics, Institute of Analytical Chemistry, Leipziger Str. 29, D-09599 Freiberg, Germany. Anne-Christine.Schmidt@chemie.tu-freiberg.de
Abstract:
Arsenic-binding proteins are of toxicological importance since enzymatic activities can be blocked by arsenic interactions. In the present work, a novel methodology based on size exclusion chromatography coupled to electrospray ionization mass spectrometry (SEC-ESI-MS) was developed with special emphasis to preserve the intact proteins and their arsenic bindings. The eluent composition of 25 mMTris/HCl, pH 7.5, with the addition of 100-mM NaCl optimized for SEC with UV detection provided the highest SEC separation efficiency, but was not compatible with the ESI-MS because of the non-volatility of the buffer substance and of the salt additive. In order to find the best compromise between chromatographic separation and ionization of the arsenic-binding proteins, buffer type and concentration, pH value, portion of organic solvent in the SEC eluent as well as the flow rate were varied. In the optimized procedure five different arsenic-binding peptides and proteins (glutathione, oxytocin, aprotinin, alpha-lactalbumin, thioredoxin) covering a molar mass range of 0.3-14 kDa could be analyzed using 75% 10-mM ammonium formate, pH 5.0/25% acetonitrile (v : v) as eluent and a turbo ion spray source operated at 300 degrees C and 5.5 kV. A complete differentiation of all peptides and proteins involved in the arsenic-binding studies as well as of their arsenic-bound forms has become feasible by means of the extracted ion chromatograms (XIC) of the mass spectrometric detection. The new method offered the possibility to estimate equilibrium constants for the reaction of phenylarsine oxide with different thiol-containing biomolecules by means of the XIC peak areas of reactants and products. Limits of detection in the range of 2-10 microM were obtained by SEC-ESI-MS for the individual proteins.
More Related Videos
12:59A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Related Concept Videos
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.