Electron Emission from Foils and Biological Materials after Proton Impact

Michael Dingfelder1, Anderson Travia, Robert A McLawhorn

  • 1Department of Physics, East Carolina University, Howell Science Complex, Greenville, NC 27858, USA.

Radiation Physics and Chemistry (Oxford, England : 1993)
|February 13, 2009
PubMed

Related Concept Videos

Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Types of Radioactivity03:23

Types of Radioactivity

The most common types of radioactivity are α decay, β decay, γ decay, neutron emission, and electron capture.
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Interaction of EM Radiation with Matter: Spectroscopy01:12

Interaction of EM Radiation with Matter: Spectroscopy

Electromagnetic (EM) radiation can be considered an oscillating electric and magnetic field propagating through a medium that can interact with matter in its path. The electric field in the radiation can interact with electrical charges in the atoms or molecules in the matter. On the other hand, the magnetic field can interact with the magnetic field in the atomic nucleus. The study of the interaction between electromagnetic radiation and matter is termed spectroscopy. Spectroscopy is the study...