Related Experiment Video
Updated: Jun 25, 2026

07:12
A Colorimetric Method for Measuring Iron Content in Plants
Published on: September 7, 2018
Estimating amounts of iron oxide from gradient echo images
W Thomas Dixon1, Daniel J Blezek, Lisa A Lowery
1General Electric Global Research, Niskayuna, NY 12309, USA. dixonwt@crd.ge.com
Magnetic Resonance in Medicine
|February 14, 2009
Summary
Accurately quantifying iron in SPIO injections requires advanced MRI techniques. Dual-echo gradient-echo imaging with phase difference analysis provides reliable iron content estimates, overcoming limitations of signal void methods.
Area of Science:
- Biomedical Engineering
- Magnetic Resonance Imaging
- Nanotechnology
Background:
- Superparamagnetic iron oxide (SPIO) nanoparticles are used in biomedical imaging.
- Accurate quantification of SPIO concentration is crucial for diagnostic and therapeutic applications.
- Traditional methods using signal void volumes in MRI are prone to errors.
Purpose of the Study:
- To develop and validate a more accurate method for quantifying iron content from SPIO injections using MRI.
- To compare the effectiveness of signal void volume estimation versus phase difference analysis.
Main Methods:
- Dual-echo, gradient-echo MRI was performed on rat legs injected with SPIO nanoparticles.
- Iron content was initially estimated using a point dipole model and signal void volumes.
- A novel approach utilized phase differences between dual-echo images, fitting a spatial phase distribution model.
- The dual-echo phase difference method was evaluated for accuracy and independence from sample orientation and echo time.
Main Results:
- Signal void volume measurements yielded inaccurate and orientation/echo time-dependent iron estimates.
- For a 3-microg iron injection, signal void volumes suggested 6-10 microg of iron.
- The dual-echo phase difference method provided consistent estimates (2.48 +/- 0.26 microg std) independent of orientation.
- Control regions showed negligible background iron estimates (-90 to -140 ng).
Conclusions:
- Dual-echo gradient-echo MRI with phase difference analysis offers a robust and accurate method for quantifying SPIO iron content.
- This technique overcomes the limitations of signal void volume measurements, improving reliability in MRI-based SPIO quantification.