Related Experiment Video
Updated: Jun 25, 2026

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Application of liquid chromatography-mass spectrometry to measure short chain fatty acids in blood
Hans M H van Eijk1, Johanne G Bloemen, Cornelis H C Dejong
1Maastricht University Medical Centre, Department of Surgery, NUTRIM School for Nutrition, Toxicology & Metabolism, P.O. Box 616, NL-6200 MD Maastricht, The Netherlands.
Abstract:
A new liquid chromatography-mass spectrometry method is described to determine concentrations of the short chain fatty acids acetic acid, propionic acid and butyric acid (SCFAs) in human blood plasma. The method is based on reversed phase chromatography followed by post-column neutralization of the mobile phase with ammonia and a consecutive measurement of the SCFAs ammonia adducts using negative electro spray ionization. Sample preparation involved simple organic acid deproteinization, resulting in 100% recovery. SCFAs eluted baseline separated within a 25 min run cycle. A linear response was obtained in the range between 0 and 250 micromol/l (R(2) ranged from 0.997 to 0.9999). The limit of detection ranged from 0.05 micromol/l for propionic and butyric acid and 0.1 micromol/l for acetic acid. The method was tested by analyzing plasma of arterial blood, from portal vein and hepatic vein blood from patients undergoing a pylorus-preserving pancreaticoduodenectomy. As expected, the highest SCFA concentrations were found in portal plasma, hepatic vein levels were in between, while arterial concentrations were lowest. This newly developed method is suitable to determine SCFA concentrations in human plasma samples.
More Related Videos
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
MALDI-TOF Mass Spectrometry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...