Related Experiment Video
Updated: Jun 25, 2026

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
Biological filtration for removal of arsenic from drinking water
Damodar Pokhrel1, Thiruvenkatachari Viraraghavan
1Stantec Consulting Ltd, Regina, SK, Canada.
Abstract:
The main objective of the study was to find a suitable iron to arsenic ratio in water to reduce arsenic to 5 microg/L or lower through sand filtration. Experiments were conducted by varying the quantity of iron(II) while keeping the arsenic concentration at 100 microg/L. A mixture of iron (II) and arsenic at different ratios (10:1, 20:1, 30:1 and 40:1) was pumped to the sand filters in a down flow mode and effluent arsenic and iron were analyzed. It was found that a ratio of iron to arsenic of 40:1 was necessary to ensure an effluent arsenic concentration of 5 microg/L or lower. Iron in the filtrate was found to be below 0.1 mg/L at all times.
More Related Videos
Related Concept Videos
Microbial Bioremediation of Uranium
Biological Treatment of Effluent and Waste Water
Filtration
Microbial Leaching
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Precipitation and Co-precipitation