Related Experiment Video
Updated: Jun 25, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG
Fuminari Tatsugami1, Lars Husmann, Bernhard A Herzog
1Department of Medical Radiology and the Cardiovascular Center, University Hospital Zurich, Raemistrasse 100, NUK C 32, CH-8091 Zurich, Switzerland.
Objective:
Because an increase in body mass index (weight in kilograms divided by height squared in meters) confers higher image noise at coronary CT angiography, we evaluated a body mass index-adapted scanning protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering.
Subjects And Methods:
One hundred one consecutively registered patients underwent coronary CTA with prospective ECG triggering with a fixed contrast protocol (80 mL of iodixanol, 50-mL saline chaser, flow rate of 5 mL/s). Tube voltage (range, 100-120 kV) and current (range, 450-700 mA) were adapted to body mass index. Attenuation was measured, and contrast-to-noise ratio was calculated for the proximal right coronary artery and left main coronary artery. Image noise was determined for each patient as the SD of attenuation in the ascending aorta.
Results:
Body mass index ranged from 18.2 to 38.8, and mean effective radiation dose from 1.0 to 3.2 mSv. There was no correlation between body mass index and image noise (r = 0.11, p = 0.284), supporting the validity of the body mass index-adapted scanning protocol. However, body mass index was inversely correlated with vessel attenuation (right coronary artery, r = -0.45, p < 0.001; left main coronary artery, r = -0.47, p < 0.001) and contrast-to-noise ratio (right coronary artery, r = -0.39, p < 0.001; left main coronary artery, r = -0.37, p < 0.001).
Conclusion:
Use of the proposed body mass index-adapted scanning parameters results in similar image noise regardless of body mass index. Increased bolus dilution due to larger blood volume may account for the decrease in contrast-to-noise ratio and vessel attenuation in patients with higher body mass index, but the contrast bolus was not adapted to body mass index in this study.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System IV: CMRI
Acute Coronary Syndrome III: Diagnostic Studies
Cardiac Catheterization I: Pre-Procedure Overview
