Evaluation of a solution isoelectric focusing protocol as an alternative to ion exchange chromatography for
John C Tran1, Mark J Wall, Alan A Doucette
1Department of Chemistry, Dalhousie University, 6274 Coburg Road, Halifax, Nova Scotia, Canada B3H 4J3.
Abstract:
Solution isoelectric focusing (sIEF) is evaluated relative to ion exchange chromatography (IEC) as a preferred charge-based prefractionation tool for proteome mixtures. While IEC is extensively employed for proteome prefractionation prior to MS analysis, we demonstrate here that conventional salt gradient IEC has significant shortcomings compared to sIEF. Here, we critically evaluated a custom eight-channel sIEF device for intact protein separation, relative to strong cation exchange (SCX) and strong anion exchange (SAX) chromatography. The resolution, recovery, and uniformity of separation obtained with our sIEF device were comparable or superior to that of optimized IEC separations. Most importantly for intact proteins, sIEF separations strongly correlate with the proteins' isoelectric point, which contrasts with IEC where no correlation was observed. To validate the sIEF platform for proteome analysis, prefractionation through sIEF resulted in the confident identification of a greater number of proteins from yeast (211) following LC-MS/MS, relative to those obtained through SAX (173) or SCX (148).
More Related Videos
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
07:58Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Related Concept Videos
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Electrophoresis: Overview
There...
Ion Exchange