Related Experiment Video
Updated: Jun 25, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Recording of peak endocardial acceleration in the atrium
Daniel Gras1, Luc Kubler, Philippe Ritter
1Nouvelles Cliniques Nantaises, Nantes, France. Dangras@aol.com
Background:
The important role played by peak endocardial acceleration (PEA or sonR) in hemodynamic monitoring of cardiac resynchronization therapy (CRT) was recently highlighted in several studies with the sensor embedded in a right ventricular (RV) lead tip. This study examined the short- and long-term reliability of a right atrial (RA) sonR sensor.
Methods:
RA and RV sonR signals were measured from RA and RV leads respectively, at implant and up to 12 months of follow-up, in 19 recipients of either single chamber pacemakers or CRT systems. At 1 month of follow up, RA sonR signals and heart rate were simultaneously recorded during exercise.
Results:
A reliable RA sonR signal amplitude was measured at implant, proportional to the RV amplitude. We observed in both the right atrium and right ventricle (1) a similar signal noise ratio at implant, (2) a similar evolution of the sonR signal amplitude up to 12 months of follow-up, and (3) a high correlation between heart rate and RA sonR signal amplitude during exercise.
Conclusions:
The RA sonR signal was reliable and proportional to the RV signal on the short and long term, and reflected changes in activity. These observations suggest that the sonR sensor could be placed in the atrium for the hemodynamic monitoring of CRT system recipients.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
Assessment of apical pulse