Automated immunoassay system for AFP-L3% using on-chip electrokinetic reaction and separation by affinity
Chiaki Kagebayashi1, Isao Yamaguchi, Ayumi Akinaga
1Osaka Research Laboratory, New Diagnostics Business and Technology Development Department, Wako Pure Chemical Industries Ltd., 6-1 Takada-cho, Amagasaki, Hyogo Prefecture, Japan.
Abstract:
Implementation of the on-chip immunoassay for alpha-fetoprotein (AFP)-L3% was achieved using a fully automated microfluidic instrument platform that will prepare the chip and run the assay with a total assay time of less than 10min. Reagent/sample mixing, concentration, and reaction in microfluidic channels occur by the electrokinetic analyte transport assay (EATA) technique, enabling the integration of all assay steps on-chip. The determination of AFP-L3%, a biomarker for hepatocellular carcinoma, was achieved by the presence of Lens culinaris agglutinin in the separation channel, causing separation of the fucosylated isoform, AFP-L3, from the nonfucosylated AFP-L1 by lectin affinity electrophoresis. Laser-induced-fluorescence (LIF) detection was used to quantitate the labeled immunocomplexes. The limit of detection (LOD) was 0.1ng/ml AFP, and assay precision of less than 2% coefficient of variation (CV) was obtained for quantitation from 24 to 922ng/ml total AFP in spiked serum samples. Assay precision of less than 3% CV was obtained for AFP-L3% measurements from 8.5 to 81%. Furthermore, good correlation of test results for 68 patient serum samples with a commercially available reference method (LiBASys assay for AFP-L3%) was obtained, with r(2)=0.981 and slope=1.03.
More Related Videos
09:32Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Capillary Electrophoresis: Instrumentation
Affinity Chromatography