Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Structural Ordering and Polarizable Al<sup>3+</sup> Solvation Induced via Amphiphilic Zwitterion for Highly-Reversible Zn-Al Alloy Anodes.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Renal involvement in different subtypes of children with juvenile idiopathic arthritis: results from a single-center cohort.

Clinical rheumatology·2026
Same author

Full-Process Proton Management Unlocks Long-Life Aqueous Zinc-Metal Batteries.

ACS nano·2026
Same author

All-fibre-coupled terahertz single-pixel imaging for biomedical applications.

Nature communications·2026
Same author

Self-Assembled Ordered Nanostructure of Zwitterionic Co-Solutes Induces Localized High-Concentration Electrolytes for Ultrastable and Efficient Zinc Metal Anodes.

Nano-micro letters·2026
Same author

Multi-layered model for simulating the <i>in vivo</i> terahertz response of human skin.

Biomedical optics express·2025

Related Experiment Video

Updated: Jun 25, 2026

Terahertz Imaging and Characterization Protocol for Freshly Excised Breast Cancer Tumors
08:56

Terahertz Imaging and Characterization Protocol for Freshly Excised Breast Cancer Tumors

Published on: April 5, 2020

Improved sample characterization in terahertz reflection imaging and spectroscopy.

Shengyang Huang1, Philip C Ashworth, Kanis W Kan

  • 1Department of Electronic Engineering, Chinese University of Hong Kong, NT, Hong Kong.

Optics Express
|March 5, 2009
PubMed
Summary
This summary is machine-generated.

Terahertz pulsed imaging in reflection geometry can be improved by a new method that accounts for unwanted window reflections. This technique enhances optical property calculations for biological imaging applications.

More Related Videos

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
13:44

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers

Published on: December 27, 2012

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

Related Experiment Videos

Last Updated: Jun 25, 2026

Terahertz Imaging and Characterization Protocol for Freshly Excised Breast Cancer Tumors
08:56

Terahertz Imaging and Characterization Protocol for Freshly Excised Breast Cancer Tumors

Published on: April 5, 2020

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
13:44

Simulation, Fabrication and Characterization of THz Metamaterial Absorbers

Published on: December 27, 2012

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

Area of Science:

  • Biomedical imaging
  • Terahertz spectroscopy
  • Optics

Background:

  • Terahertz pulsed imaging (TPI) is valuable for biological subjects.
  • Water's high attenuation of terahertz radiation necessitates reflection geometry.
  • Interference from system windows complicates TPI in reflection mode.

Purpose of the Study:

  • To develop a novel approach for mitigating unwanted reflections in terahertz reflection imaging.
  • To improve the accuracy of optical property calculations for biological samples using TPI.

Main Methods:

  • Derivation of a new mathematical model to correct for window reflections.
  • Application of the model to terahertz reflection data from biological samples.

Main Results:

  • Successfully accounted for the effects of window reflections.
  • Demonstrated improved calculations of sample optical properties.
  • Validated the new approach for terahertz reflection imaging.

Conclusions:

  • The developed method effectively removes interference from window reflections.
  • This advancement enhances the utility of terahertz pulsed imaging for biological applications.
  • Accurate optical property determination is crucial for interpreting TPI data.