Related Experiment Video
Updated: Jun 25, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Retinal blood flow detection in diabetic patients by Doppler Fourier domain optical coherence tomography
Yimin Wang1, Amani Fawzi, Ou Tan
1Center for Ophthalmic Optics & Lasers, Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA. yiminwan@usc.edu
Abstract:
We present human retinal blood flow investigation for diabetic patients using Doppler Fourier domain optical coherence tomography (FDOCT). The scanning pattern consisted of two concentric circles around the optic nerve head. The blood flow in one patient with diabetes and no retinpathy and another patient with treated proliferative diabetic retinopathy were measured. The patient without retinopathy showed a total blood flow value at the lower level of the normal range. The flow distribution between superior and inferior retina was balanced. The patient with diabetic retinopathy had a flow value lower than the normal people. Our study shows that Doppler FD-OCT can be used to evaluate the total retinal blood flow in patients with retinal diseases.
Related Concept Videos
Diabetic Retinopathy
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: