Related Experiment Video
Updated: Jun 24, 2026

Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Precision of time devices used by prehospital providers
Adam N Frisch1, Michael W Dailey, Daniel Heeren
1Department of Emergency Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
Background:
As many medical, medicolegal, and research interests have become more time-dependent, increased weight should be placed on the precision of time documentation and timing devices. Studies have previously documented poor synchronization of timing devices in the medical setting. Objective. To determine whether any advancement has been made in prehospital time accuracy and to determine the timing devices used by today's emergency medical services (EMS) providers.
Methods:
Times recorded from the timing devices available for use during calls by local EMS providers, including watches, cellular phones, cardiac monitors/ defibrillators, ambulance clocks, and public safety answering points, were compared with atomic time to determine accuracy. Additionally, the preferred provider timing device, and accuracy of said device, was obtained.
Results:
A total of 138 available timing devices were observed, with an accuracy of only 36.9%; cell phones had the best accuracy (67.7%). For the 53 providers surveyed, watches (64.2%) were found to be the most used timing device, followed by cell phones (24.5%) and ambulance clocks (11.3%). Only 18 (34.0%) of these preferred devices were accurate when compared with atomic time.
Conclusions:
There is no precision or consistency in the timing devices used by EMS personnel. However, methods are available, such as those that support the cellular phone industry, that would help with consistent and precise timekeeping. Utilization of modern technologies could increase precision in patient documentation and decrease medical, medicolegal, and research issues relating to time documentation.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Field Application of Global Positioning System
Electronic Distance Measuring Instruments
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...