Cardiac output by arterial pulse contour: reliability under hemodynamic derangements
Stefano Romagnoli1, Salvatore Mario Romano, Sergio Bevilacqua
1Department of Heart and Vessels, Careggi Hospital, Florence, Italy. stefano.romagnoli@fastdigitel.com
Abstract:
Pulse contour methods (PCM) for the measurements of cardiac output (CO) are gaining popularity in intensive care settings but their reliability during hemodynamic instability has been questioned. Pressure-recording-analytical-method (PRAM) is a newly developed uncalibrated hemodynamic monitor and its capability in measuring CO during hemodynamic instability is still under investigation. Dobutamine (2.5 and 5 microg/kg/min), vasoconstriction (arginine-vasopressin 4, 8 and 16 IU/h), hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia), and volume resuscitation were induced in eight swine. CO by means of thermodilution (CO(ThD)), transesophageal echocardiography (CO(TEE)) and PRAM (CO(PRAM)) were contemporarily registered. R(2), bias, and percentage error were used to compare the methods. Comparison between CO(PRAM) and CO(ThD) resulted in: r(2)=0.87; bias=-0.006 l/min; precision=+/-0.87 l/min; percentage error=22.8%. Comparison between CO(PRAM) and CO(TEE) resulted in: r(2)=0.85; bias=-0.007 l/min; precision=+/-0.86 l/min; percentage error=22%. Sub-group analysis revealed disagreement between methods only during the last two steps of hemorrhage: CO(PRAM) vs. CO(ThD): r(2)=0.67, bias=-0.37 l/min, precision=+/-1.04 l/min, limits of agreement=-1.39+0.66 l/min, and percentage error=45%; CO(PRAM) vs. CO(TEE): r(2)=0.38, bias=0.4 l/min, precision=+/-1.42 l/min, limits of agreement=-0.99+1.79 l/min, and percentage error=62%. PRAM resulted to be accurate in measuring CO during hemodynamic stability, tachycardia, and vasoconstriction. When volemia was reduced by >35%, disagreement between methods was observed.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection