Related Experiment Video
Updated: Jun 24, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Massive intraoperative thrombus of the aortic arch and proximal descending aorta
David C Reineke1, Martin T R Grapow, Martin Schumann
1Department of Cardiovascular Surgery, University Hospital, Freiburgstrasse, Bern, Switzerland. dr.d.reineke@gmail.com
Abstract:
A 49-year-old male patient presented with a paravalvular leakage 18 years after aortic valve replacement. The patient received a mechanical valve and was weaned uneventfully from cardiopulmonary bypass. After a drop in the pressure curve of the left radial artery an additional line was placed in the proximal ascending aorta showing normal systemic pressure. Transesophageal echocardiography showed a massive circular thrombosis of the distal aortic arch. The patient received a covered stent to expand the residual aortic lumen and left the hospital in good health.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Aneurysm I: Introduction
Thoracic Aorta
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
Aneurysm III: Interprofessional Care