Related Experiment Video
Updated: Jul 19, 2025

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Hyperoxia-induced deterioration of diastolic function in anaesthetised patients with coronary artery disease -
Jan O Friess1,2, Jan Mikasi1, Rico Baumann1
1Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Background:
There are no current recommendations for oxygen titration in patients with stable coronary artery disease. This study investigates the effect of iatrogenic hyperoxia on cardiac function in patients with coronary artery disease undergoing general anaesthesia.
Methods:
Patients scheduled for elective coronary artery bypass graft surgery were prospectively recruited into this randomised crossover clinical trial. All patients were exposed to inspired oxygen fractions of 0.3 (normoxaemia) and 0.8 (hyperoxia) in randomised order. A transoesophageal echocardiographic imaging protocol was performed during each exposure. Primary analysis investigated changes in 3D peak strain, whereas secondary analyses investigated other systolic and diastolic responses.
Results:
There was no statistical difference in systolic function between normoxaemia and hyperoxia. However, the response in systolic function to hyperoxia was dependent on ventricular function at normoxaemia. Patients with a normoxaemic left ventricular (LV) global longitudinal strain (GLS) poorer than the derived cut-off (>-15.4%) improved with hyperoxia (P<0.01), whereas in patients with normoxaemic LV-GLS <-15.4%, LV-GLS worsened with transition to hyperoxia (P<0.01). The same was seen for right ventricular GLS with a cut-off at -24.1%. Diastolic function worsened during hyperoxia indicated by a significant increase of averaged E/e' (8.6 [2.6]. vs 8.2 [2.4], P=0.01) and E/A ratio (1.4 (0.4) vs 1.3 (0.4), P=0.01).
Conclusions:
Although the response of biventricular systolic variables is dependent on systolic function at normoxaemia, diastolic function consistently worsens under hyperoxia. In coronary artery disease, intraoperative strain analysis may offer guidance for oxygen titration.
Clinical Trial Registration:
NCT04424433.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Oxygen Transport in the Blood
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure