Learning curve of vitrification assessed by cumulative summation test for learning curve (LC-CUSUM)

Lionel Dessolle1, David J Biau2, Vanina de Larouzière3

  • 1Service d'histologie et biologie de la reproduction, Assistance Publique Hôpitaux de Paris (APHP) - Hôpital Tenon, Paris, France; Service de gynécologie obstétrique et médecine de la reproduction, APHP-Hôpital Tenon, Paris, France; EA-1533, Université Paris VI, Paris, France.

Related Concept Videos

In Vitro Drug Dissolution: Compendial Testing Models II01:09

In Vitro Drug Dissolution: Compendial Testing Models II

Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients, maintaining...
In Vitro Drug Dissolution: Compendial Testing Models I01:13

In Vitro Drug Dissolution: Compendial Testing Models I

Compendial dissolution methods are standardized procedures defined by pharmacopeias to evaluate the rate at which a drug dissolves in a specific medium. These methods ensure batch-to-batch consistency, enable quality control, and support the prediction of drug bioavailability. They are critical for both immediate and modified-release drug products.The apparatuses used for dissolution testing differ in their design and mechanical function, but all aim to simulate the physiological environment of...
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Area Problem01:26

Area Problem

Determining the area of a region with straight edges is straightforward, as geometric formulas for rectangles, triangles, and polygons can be applied directly. However, traditional geometric methods are insufficient when a region has a curved boundary, such as the area under a function.fromThe area problem involves finding a systematic way to measure such regions. One approach to solving this problem is through approximation. Instead of attempting to compute the area exactly at the outset, the...