Analysis of polychlorinated biphenyls in human serum by gas chromatography-mass selective detection operating at high
Buu N Tran1, Li Zhang, Robert Jansing
1Wadsworth Center for Laboratories and Research, New York State Department of Health, Albany, NY 12201-0509, USA. btran@wadsworth.org
Abstract:
Optimization of analytical instrumentation is essential when analyses of persistent organic pollutants in human serum are performed at ultra-trace levels. This research describes the analysis of polychlorinated biphenyls (PCBs) in serum using gas chromatography coupled with a mass selective detector (GC/MSD) in the selected ion monitoring (SIM) mode. We selected PCB-58 and PCB-186 as internal standards (ISs) for the method development, and newborn calf serum (NCS) was chosen as the matrix. The matrix was fortified with PCB congeners and extracted by an automated solid phase extraction system using C18 sorbent. The extracts were analyzed at two ion source temperatures, 230 and 300 degrees C. The use of high ion source temperature increased the abundances of high-mass ions, and the response factors in SIM mode for PCBs. An excellent linearity from 0.5 to 100 ng/ml at ion source temperature of 300 degrees C was demonstrated, with a calculated detection limit of 0.1 ng/g serum. Seven replicate fortifications of newborn calf serum, at three spiking levels of 1, 10, and 50 ng/g of serum, gave mean recoveries of 110%, 85%, and 98%, with average relative standard deviation (RSD) values of 5.4%, 7.3%, and 4.7%, respectively.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview