Synthetic wavelength based phase unwrapping in spectral domain optical coherence tomography
Hansford C Hendargo1, Mingtao Zhao, Neal Shepherd
1Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA. Hansford.Hendargo@duke.edu
Abstract:
Phase sensing implementations of spectral domain optical coherence tomography (SDOCT) have demonstrated the ability to measure nanometer-scale temporal and spatial profiles of samples. However, the phase information suffers from a 2pi ambiguity that limits observations of larger sample displacements to lengths less than half the source center wavelength. We introduce a synthetic wavelength phase unwrapping technique in SDOCT that uses spectral windowing and corrects the 2pi ambiguity, providing accurate measurements of sample motion with information gained from standard SDOCT processing. We demonstrate this technique by using a common path implementation of SDOCT and correctly measure phase profiles from a phantom phase object and human epithelial cheek cells which produce multiple wrapping artifacts. Using a synthetic wavelength for phase unwrapping could prove useful in Doppler or other phase based implementations of OCT.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
IR Frequency Region: X–H Stretching
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...