Contrast improvement in Fourier-domain optical coherence tomography through time gating
Matthew S Muller1, James M Fraser
1Department of Physics, Engineering Physics & Astronomy, Queen's University, Kingston, Ontario K7L 3N6, Canada.
Abstract:
Time-gated (TG) Fourier-domain optical coherence tomography (FDOCT) exploits interferometric imaging with incoherent gating to filter out unwanted backreflections and improve contrast. The system uses sum-frequency generation with a variable length optical pulse as a "time gate" to restrict the depth field of view of backscattered light to 84-176 microm (-20 dB points). The imaging bandwidth is upconverted from the IR (1280 nm) to visible (504 nm), which allows the use of sensitive silicon-based detection technology, prior to standard FDOCT processing. The TG system achieves a maximum sensitivity of 88 dB, and a contrast enhancement of 29 dB is shown over a standard IR FDOCT system. Imaging of a highly scattering medium (onion skin) is also demonstrated.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Continuous -time Fourier Transform
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length, the...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...