Related Experiment Video
Updated: Jun 24, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Chemoinformatic methods for predicting interference in drug of abuse/toxicology immunoassays
Matthew D Krasowski1, Mohamed G Siam, Manisha Iyer
1Department of Pathology, University of Pittsburgh, Pittsburgh, PA 15261, USA. mdk24@pitt.edu.
Background:
Immunoassays used for routine drug of abuse (DOA) and toxicology screening may be limited by cross-reacting compounds able to bind to the antibodies in a manner similar to the target molecule(s). To date, there has been little systematic investigation using computational tools to predict cross-reactive compounds.
Methods:
Commonly used molecular similarity methods enabled calculation of structural similarity for a wide range of compounds (prescription and over-the-counter medications, illicit drugs, and clinically significant metabolites) to the target molecules of DOA/toxicology screening assays. We used various molecular descriptors (MDL public keys, functional class fingerprints, and pharmacophore fingerprints) and the Tanimoto similarity coefficient. These data were then compared with cross-reactivity data in the package inserts of immunoassays marketed for in vitro diagnostic use. Previously untested compounds that were predicted to have a high probability of cross-reactivity were tested.
Results:
Molecular similarity calculated using MDL public keys and the Tanimoto similarity coefficient showed a strong and statistically significant separation between cross-reactive and non-cross-reactive compounds. This result was validated experimentally by discovery of additional cross-reactive compounds based on computational predictions.
Conclusions:
The computational methods employed are amenable toward rapid screening of databases of drugs, metabolites, and endogenous molecules and may be useful for identifying cross-reactive molecules that would be otherwise unsuspected. These methods may also have value in focusing cross-reactivity testing on compounds with high similarity to the target molecule(s) and limiting testing of compounds with low similarity and very low probability of cross-reacting with the assay.
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Therapeutic Drug Monitoring: Drug Analysis Methods
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Drug toxicity: Drug–Drug Interaction