Related Experiment Video
Updated: Jun 24, 2026

Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
Published on: May 23, 2025
Imaging sequences for intraoperative MR-guided laparoscopic liver resection in 1.0-T high field open MRI
S S Chopra1, J Rump, S C Schmidt
1Department of General, Visceral and Transplantation Surgery, Charité Campus Virchow Clinic, University Medicine Berlin, Augustenburger Platz 1, Berlin 13353, Germany. sascha.chopra@charite.de
Abstract:
The aim of this study was to identify suitable interactive (dynamic) magnetic resonance (MR) sequences for real-time MR-guided liver dissection in a 1.0-T high field open MRI system. Four dynamic sequences encompassing balanced steady state free precession (bSSFP), T1W gradient echo (GRE), T2W GRE and T2W fast spin echo (FSE) were analysed regarding the image quality, artefact susceptibility and the performance of SNR and CNR. The T2W FSE sequence (1.5 s/image) was considered superior because of an intraoperative SNR of 6.9 (+/-0.7) and CNR (vessel to parenchyma) of 5.6 (+/-1.7) in the interventional setting. As a proof of concept, MR-guided laparoscopic liver resection was performed in two healthy domestic pigs by using the T2W FSE sequence. The additional MR images offered simultaneous multiplanar real-time visualisation of the liver vessels during the intervention and thereby increased the anatomical orientation of the surgeon.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging