Related Experiment Video
Updated: Jun 24, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Chlorine dioxide reactions with indoor materials during building disinfection: surface uptake
Heidi Hubbard1, Dustin Poppendieck, Richard L Corsi
1Research Triangle Park, United States Environmental Protection Agency, North Carolina 27711, USA.
Abstract:
Chlorine dioxide received attention as a building disinfectant in the wake of Bacillus anthracis contamination of several large buildings in the fall of 2001. It is increasingly used for the disinfection of homes and other indoor environments afflicted by mold. However, little is known regarding the interaction of chlorine dioxide and indoor materials, particularly as related to the removal of chlorine dioxide from air. Such removal may be undesirable with respect to the subsequent formation of localized zones of depleted disinfectant concentrations and potential reductions in disinfection effectiveness in a building. The focus of this paper is on chlorine dioxide removal from air to each of 24 different indoor materials. Experiments were completed with materials housed in flow-through 48-L stainless steel chambers under standard conditions of 700 ppm chlorine dioxide inlet concentration, 75% relative humidity, 24 degrees C, and 0.5 h(-1) air changes. Chlorine dioxide concentration profiles, deposition velocities, and reaction probabilities are described in this paper. Deposition velocities and reaction probabilities varied over approximately 2 orders of magnitude across all materials. For most materials, deposition velocity decreased significantly over a 16-h disinfection period; that is, materials became smaller sinks for chlorine dioxide with time. Four materials (office partition, ceiling tile, medium density fiberboard, and gypsum wallboard) accounted for the most short- and long-term consumption of chlorine dioxide. Deposition velocity was observed to be a strong function of chlorine dioxide inlet concentration, suggesting the potential importance of chemical reactions on or within test materials.
More Related Videos
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
06:27Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Related Concept Videos
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Microbial Bioremediation of Pesticides
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Oxidation-Reduction Reactions
Hand hygiene
Hand washing...